Wei Shao (University of California, Davis), Zequan Liang (University of California Davis), Ruoyu Zhang (University of California, Davis), Ruijie Fang (University of California, Davis), Ning Miao (University of California, Davis), Ehsan Kourkchi (University of California - Davis), Setareh Rafatirad (University of California, Davis), Houman Homayoun (University of California Davis), Chongzhou Fang (Rochester Institute of Technology)

Biometric authentication using physiological signals offers a promising path toward secure and user-friendly access control in wearable devices. While electrocardiogram (ECG) signals have shown high discriminability, their intrusive sensing requirements and discontinuous acquisition limit practicality. Photoplethysmography (PPG), on the other hand, enables continuous, non-intrusive authentication with seamless integration into wrist-worn wearable devices. However, most prior work relies on high-frequency PPG (e.g., 75–500 Hz) and complex deep models, which incur significant energy and computational overhead—impeding deployment in power-constrained real-world systems. In this paper, we present the first real-world implementation and evaluation of a continuous authentication system on a smartwatch, We-Be Band, using low-frequency (25 Hz) multi-channel PPG signals. Our method employs a Bi-LSTM with attention mechanism to extract identity-specific features from short (4 s) windows of 4-channel PPG. Through extensive evaluations on both public datasets (PTTPPG) and our WeBe Dataset (26 subjects), we demonstrate strong classification performance with an average test accuracy of 88.11%, macro F1-score of 0.88, False Acceptance Rate (FAR) of 0.48%, False Rejection Rate (FRR) of 11.77%, and Equal Error Rate (EER) of 2.76%. Our 25 Hz system reduces sensor power consumption by 53% compared to 512 Hz and 19% compared to 128 Hz setups without compromising performance. We find that sampling at 25 Hz preserves authentication accuracy, whereas performance drops sharply at 20 Hz while offering only trivial additional power savings, underscoring 25 Hz as the practical lower bound. Additionally, we find that models trained exclusively on resting data fail under motion, while activity-diverse training improves robustness across physiological states.

View More Papers

Huma: Censorship Circumvention via Web Protocol Tunneling with Deferred...

Sina Kamali (University of Waterloo), Diogo Barradas (University of Waterloo)

Read More

Hiding an Ear in Plain Sight: On the Practicality...

Youqian Zhang (The Hong Kong Polytechnic University), Zheng Fang (The Hong Kong Polytechnic University), Huan Wu (The Hong Kong Polytechnic University & Technological and Higher Education Institute of Hong Kong), Sze Yiu Chau (The Chinese University of Hong Kong), Chao Lu (The Hong Kong Polytechnic University), Xiapu Luo (The Hong Kong Polytechnic University)

Read More

Enhancing Semantic-Aware Binary Diffing with High-Confidence Dynamic Instruction Alignment

Chengfeng Ye (The Hong Kong University of Science and Technology, China), Anshunkang Zhou (The Hong Kong University of Science and Technology, China), Charles Zhang (The Hong Kong University of Science and Technology, China)

Read More